Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.994
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Clin Cardiol ; 47(5): e24272, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38742736

RESUMO

Paravalvular leak (PVL) is an uncommon complication of prosthetic valve implantation, which can lead to infective endocarditis, heart failure, and hemolytic anemia. Surgical reintervention of PVLs is associated with high mortality rates. Transcatheter PVL closure (TPVLc) has emerged as an alternative to surgical reoperation. This method provides a high success rate with a low rate of complications. This article reviews the pathogenesis, clinical manifestation, diagnosis, and management of PVL and complications following TPVLc. Besides, we presented a case of a patient with severe PVL following mitral valve replacement, who experienced complete heart block (CHB) during TPVLc. The first TPVLc procedure failed in our patient due to possible AV-node insult during catheterization. After 1 week of persistent CHB, a permanent pacemaker was implanted. The defect was successfully passed using the previous attempt. Considering the advantages of TPVLc, procedure failure should be regarded as a concern. TPVLc should be performed by experienced medical teams in carefully selected patients.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral , Falha de Prótese , Humanos , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Ecocardiografia Transesofagiana , Masculino , Resultado do Tratamento , Feminino , Idoso , Reoperação
2.
Artigo em Inglês | MEDLINE | ID: mdl-38727533

RESUMO

Preoperative calculations showed that the 9-mm inlet, 6-mm outlet, 25-cc pump chambers and 65-73 bpm would be optimal for a 5-year-old patient suffering from restrictive cardiomyopathy, with a body surface area of 0.59 m2 (1.5 L/min flow for a cardiac index of 2.5). After re-sternotomy and standard bicaval cannulation for cardiopulmonary bypass, the procedure was performed under normothermic conditions and on the beating heart. Biventricular support was established with the Berlin Heart Excor using biatrial cannulation. For left atrial cannulation, induced ventricular fibrillation was used. The 9-mm inlet cannulas were inserted into the left and right atria, respectively. The 6-mm outlet cannulas were implanted using 8-mm interposition vascular grafts for the aorta and the main pulmonary artery, respectively. Cannulas were tunnelled through the epigastric space, with systems crossing outside of the body. The 25-cc chambers were used for both right ventricular assist device and left ventricular assist device support, which subsequently showed full emptying and filling.


Assuntos
Cardiomiopatia Restritiva , Coração Auxiliar , Humanos , Cardiomiopatia Restritiva/cirurgia , Cardiomiopatia Restritiva/diagnóstico , Masculino , Pré-Escolar , Átrios do Coração/cirurgia , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/cirurgia , Implantação de Prótese/métodos
3.
Catheter Cardiovasc Interv ; 103(6): 995-1003, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662126

RESUMO

BACKGROUND: Limited data exists regarding incidence, progression, and predictors of left atrial appendage (LAA) sealing after transcatheter LAA closure. We aimed to evaluate the incidence, progression, and predictive factors associated with LAA sealing after LAA closure. METHODS: This study includes patients who underwent successful LAA closure with Watchman FLX device and had both pre- and postprocedural computed tomography (CT). Postprocedural CT was performed 45 days after LAA closure and used to evaluate residual LAA patency. Patient who had residual LAA patency at 45 days underwent 1-year follow-up CT. RESULTS: A total of 105 patients (mean age: 75.2 ± 9.6 years; 53.3% female) who underwent successful LAA closure with Watchman FLX device and had pre- and postprocedural CT at 45 days were included. Residual patency was observed in 35 (33.3%) patients: 21 (20.0%) patients showed complete contrast opacification in LAA (complete LAA patency) while 14 (13.3%) patients showed contrast opacification only in the distal LAA (distal LAA patency). Among patients with residual LAA patency at 45 days, the rate of LAA sealing at 1 year was significantly higher in the distal LAA patency group than in the complete LAA patency group (75.0% vs. 16.7%; p = 0.019). Increased depth oversizing was associated with both distal LAA patency and complete LAA patency. CONCLUSION: Postprocedural CT at 45 days detected patent LAA in one-third of patients after LAA closure. LAA sealing was more frequently observed at 1 year among the distal LAA patency group than the complete LAA patency group.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cateterismo Cardíaco , Valor Preditivo dos Testes , Desenho de Prótese , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Feminino , Masculino , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Resultado do Tratamento , Fatores de Tempo , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Estudos Retrospectivos , Incidência , Tomografia Computadorizada por Raios X , Tomografia Computadorizada Multidetectores
4.
Catheter Cardiovasc Interv ; 103(6): 1023-1034, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639143

RESUMO

BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.


Assuntos
Técnicas de Ablação , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica , Etanol , Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos , Masculino , Etanol/administração & dosagem , Etanol/efeitos adversos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade
5.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
6.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38597297

RESUMO

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Assuntos
Cateterismo Cardíaco , Análise de Elementos Finitos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Valva Pulmonar , Humanos , Valva Pulmonar/fisiopatologia , Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Medição de Risco , Adolescente , Resultado do Tratamento , Fatores de Risco , Masculino , Criança , Estudos Retrospectivos , Feminino , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Adulto Jovem , Valor Preditivo dos Testes , Hemodinâmica , Stents , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Tomada de Decisão Clínica , Adulto
7.
JACC Cardiovasc Interv ; 17(8): 1073-1075, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658125
8.
JACC Cardiovasc Interv ; 17(8): 1060-1062, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573255
11.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38468182

RESUMO

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Idoso , Humanos , Masculino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Vasos Coronários/diagnóstico por imagem , Oclusão do Apêndice Atrial Esquerdo , Desenho de Prótese , Dispositivo para Oclusão Septal/efeitos adversos , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
13.
Int J Cardiol ; 406: 131998, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38555057

RESUMO

BACKGROUND: Fluid-filled pressure guidewires are unaffected by the previously inevitable hydrostatic pressure gradient (HPG). This study aimed to compare simultaneous pressure measurements with fluid-filled and sensor-tipped pressure guidewires. METHODS: Fifty patients underwent fractional flow reserve (FFR) and Pd/Pa measurement with a fluid-filled and a sensor-tipped pressure guidewire simultaneously. To assess maneuverability, patients were randomized with respect to which pressure guidewire was used to cross the lesion first. Lateral fluoroscopy was used to estimate height difference between catheter tip and distal wire position (and thus HPG). Agreement between pressure measurements was studied. RESULTS: Measurements were performed in LM (4% (n = 2)), LAD (44% (n = 22)), LCX (26% (n = 13)), and RCA (26% (n = 13)). Simultaneous pressure measurements showed excellent agreement (mean FFR difference - 0.01 ± 0.03 (r = 0.959, p < 0.001), mean Pd/Pa difference - 0.01 ± 0.04 (r = 0.929, p < 0.001)). FFR was ≤0.80 in 42.6% (n = 20) with fluid-filled FFR measurements versus 46.8% (n = 22) by sensor-tipped FFR measurements. Mean height difference was 15 ± 34 mm, and strongly dependent on the coronary artery (LAD 45 ± 10 mm, LCX -23 ± 16 mm, RCA -13 ± 17 mm). There was a strong correlation between height difference and difference in pressure ratios between sensor-tipped and fluid-filled pressure guidewires (FFR r = -0.850, p < 0.001; Pd/Par = -0.641, p < 0.001). Largest FFR differences were present in the LAD (-0.04 ± 0.02). After HPG correction, mean difference between HPG-corrected sensor-tipped FFR and fluid-filled FFR was 0.00 ± 0.02, mean Pd/Pa difference was 0.01 ± 0.03. CONCLUSIONS: This study shows excellent overall correlation between FFR and Pd/Pa measurements with both pressure guidewires. Differences measured with fluid-filled and sensor-tipped pressure guidewires are vessel-specific and attributable to hydrostatic pressure gradients (NCT04802681).


Assuntos
Cateterismo Cardíaco , Reserva Fracionada de Fluxo Miocárdico , Humanos , Feminino , Masculino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Pessoa de Meia-Idade , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação , Angiografia Coronária/métodos , Desenho de Equipamento , Estudos Prospectivos
14.
Catheter Cardiovasc Interv ; 103(6): 1050-1061, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38363035

RESUMO

INTRODUCTION: Right-side infective endocarditis (RSIE) is caused by microorganisms and develops into intracardiac and extracardiac complications with high in-hospital and 1-year mortality. Treatments involve antibiotic and surgical intervention. However, those presenting with extremes e.g. heart failure, or septic shock who are not ideal candidates for conventional medical therapy might benefit from minimally invasive procedures. OBJECTIVE: This review summarizes existing observational studies that reported minimally invasive procedures to debulk vegetation due to infective endocarditis either on valve or cardiac implantable electronic devices. METHODS: A targeted literature review was conducted to identify studies published in PubMed/MEDLINE, EMBASE, and Cochrane Central Database from January 1, 2015 to June 5, 2023. The efficacy and/or effectiveness of minimally invasive procedural interventions to debulk vegetation due to RSIE were summarized following PRISMA guidelines. RESULTS: A total of 11 studies with 208 RSIE patients were included. There were 9 studies that assessed the effectiveness of the AngioVac system and 2 assessed the Penumbra system. Overall procedure success rate was 87.9%. Among 8 studies that reported index hospitalization, 4 studies reported no death, while the other 4 studies reported 10 deaths. CONCLUSIONS: This study demonstrates that multiple systems can provide minimally invasive procedure options for patients with RSIE with high procedural success. However, there are mixed results regarding complications and mortality rates. Further large cohort studies or randomized clinical trials are warranted to assess and/or compare the efficacy and safety of these systems.


Assuntos
Endocardite Bacteriana , Humanos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Endocardite/cirurgia , Endocardite/mortalidade , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/mortalidade , Endocardite Bacteriana/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Estudos Observacionais como Assunto , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Fatores de Risco , Resultado do Tratamento
16.
J Cardiovasc Comput Tomogr ; 18(3): 259-266, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38383226

RESUMO

AIM: To identify anatomical computed tomography (CT) predictors of procedural and clinical outcomes in patients undergoing tricuspid transcatheter edge-to-edge repair (T-TEER). METHODS AND RESULTS: Consecutive patients undergoing T-TEER between March 2018 to December 2022 who had cardiac CT prior to the procedure were included. CT scans were automatically analyzed using a dedicated software that employs deep learning techniques to provide precise anatomical measurements and volumetric calculations. Technical success was defined as successful placement of at least one implant in the planned anatomic location without single leaflet device attachment. Procedural success was defined as tricuspid regurgitation reduction to moderate or less. Procedural complexity was assessed by measuring the fluoroscopy time. The clinical endpoint was a composite of death, heart failure hospitalization, or tricuspid re-intervention throughout two years. A total of 33 patients (63.6% male) were included. Procedural success was achieved in 22 patients (66.7%). Shorter end-systolic (ES) height between the inferior vena cava (IVC) and tricuspid annulus (TA) (r â€‹= â€‹- 0.398, p â€‹= â€‹0.044) and longer ES RV length (r â€‹= â€‹0.551, p â€‹= â€‹0.006) correlated with higher procedural complexity. ES RV length was independently associated with lower technical(adjusted Odds ratio [OR] 0.812 [95% CI 0.665-0.991], p â€‹= â€‹0.040) and procedural success (adjusted OR 0.766, CI [0.591-0.992], p â€‹= â€‹0.043). Patients with ES right ventricular (RV) length of >77.4 â€‹mm had a four-fold increased risk of experiencing the composite clinical endpoint compared to patients with ES RV length ≤77.4 â€‹mm (HR â€‹= â€‹3.964 [95% CI, 1.018-15.434]; p â€‹= â€‹0,034]). CONCLUSION: CT-derived RV length and IVC-to-TA height may be helpful to identify patients at increased risk for procedural complexity and adverse outcomes when undergoing T-TEER. CT provides valuable information for preprocedural decision-making and device selection.


Assuntos
Cateterismo Cardíaco , Valor Preditivo dos Testes , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Resultado do Tratamento , Fatores de Risco , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Recuperação de Função Fisiológica , Tomografia Computadorizada por Raios X , Medição de Risco , Pessoa de Meia-Idade
17.
J Vet Cardiol ; 52: 35-42, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38422726

RESUMO

INTRODUCTION: Small dogs with patent ductus arteriosus (PDA) may be unable to undergo transesophageal echocardiography (TEE) with traditional probes. OBJECTIVES: To report the utility of TEE using a microprobe in dogs weighing less than 4 kg diagnosed with PDA for determination of transcatheter procedural candidacy, device selection, and intraoperative procedural guidance. ANIMALS: Eight dogs weighing less than 4 kg diagnosed with PDA. MATERIALS AND METHODS: All dogs had standard transthoracic echocardiography and microprobe TEE imaging. The quality of TEE images was graded as optimal, adequate, or poor. The ability of TEE to assess PDA anatomy, determine procedural candidacy, provide procedural guidance, detect deployed devices, and assess residual flow was recorded. RESULTS: The median age of included dogs was 6.4 months (range: 3.2-15.7 months) and the median body weight was 2.2 kg (range: 1.4-3.8 kg). Microprobe TEE images were adequate or optimal in all dogs and were integral for guiding procedural candidacy decisions. Transcatheter procedures were not pursued in two dogs based on TEE images. In the other six dogs, TEE procedural guidance was useful during transvenous (n = 5) and transarterial (n = 1) PDA occlusion attempts. Each deployed device (n = 4) was easily detected with the TEE microprobe. Real-time confirmation of adequate device sizing and placement was possible prior to release and residual flow could be monitored after release. CONCLUSIONS: Transesophageal echocardiography using a microprobe in dogs weighing less than 4 kg diagnosed with PDA allowed for characterization of PDA anatomy and determination of transcatheter procedural candidacy. Microprobe TEE images were integral for PDA device selection and offered valuable intraoperative procedural guidance.


Assuntos
Cateterismo Cardíaco , Doenças do Cão , Permeabilidade do Canal Arterial , Ecocardiografia Transesofagiana , Animais , Cães , Permeabilidade do Canal Arterial/veterinária , Permeabilidade do Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia Transesofagiana/veterinária , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/cirurgia , Cateterismo Cardíaco/veterinária , Cateterismo Cardíaco/instrumentação , Feminino , Masculino
19.
J Formos Med Assoc ; 123(5): 600-605, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38238125

RESUMO

BACKGROUND: The diameter and shape of the left atrial appendage (LAA) orifices may influence occluder selection and the outcomes of left atrial appendage closure (LAAC) procedure. This study aimed to evaluate the impact of LAA orifice diameter on the safety and efficacy of LAAC using the LAmbre device. METHODS: A total of 133 patients with nonvalvular atrial fibrillation (AF) who underwent LAAC with the LAmbre device between June 2018 and June 2020 were included in this study. The patients were categorized into two groups based on the maximal diameter of the LAA orifice: the large LAA group (n = 45) with a maximal orifice diameter of ≥31 mm, and the normal LAA group (n = 88) with a maximal orifice diameter of <31 mm. The study assessed periprocedural characteristics and long-term clinical follow-up. RESULTS: Successful implantation of the LAmbre device was observed in all patients. The incidence of periprocedural peridevice leakage (PDL) was significantly higher in the large LAA group (P < 0.001), while the incidence of acute pericardial effusion (PE) during the procedure was comparable between the two groups (P = 1.000). After a mean follow-up period of 4.8 ± 1.7 years, three patients in the large LAA group developed delayed PE, while no patients in the normal LAA group did (P = 0.037). Additionally, a larger LAA maximal orifice diameter was associated with a higher prevalence of PDL (P = 0.001) and PE (including both acute and delayed PE) (P = 0.027). The optimal cutoff value of the LAA maximal orifice diameter for predicting PDL and PE after LAAC with the LAmbre device was determined to be 30 mm. CONCLUSION: The findings suggest that the LAmbre device is a safe and feasible option for occluding the LAA, regardless of its orifice diameter. However, it is important to note that a larger LAA orifice diameter may increase the risk of PDL and delayed PE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Humanos , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Dispositivo para Oclusão Septal/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Idoso de 80 Anos ou mais , Ecocardiografia Transesofagiana , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Oclusão do Apêndice Atrial Esquerdo
20.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA